English (United Kingdom)Español(Spanish Formal International)French (Fr)
Home Library Toilets with a biogas/anaerobic digester

Library

Toilets with a biogas/anaerobic digester

Here a few information concerning conection of the pipes from the toilets to the digester:
- route the 3 pipes from the toilet cubicles into one "inlet chamber" and from there with one pipe into the digester. With this you minimize possible leakage problems in the area of pipe-wall connection.
- if available take 4" pvc pipes (4 or 6kg/cm2) from the toilte cubicles to the inlet chamber. Give a slope of 1%.
- If available take a 6" (or 4") pvc pipe from the inlet chamber into the digester.
- make the pipe inlet into the digester below the water level in the digester to prevent gas leakage.


Author:

Zimmermann, N.

Publisher:

Autark Engineering AG, Switzerland

Year:

2012

Pages:

1

Keywords:

Biogas Settler, Inlet details of biogas settler

Link:


Bibliographic information:
Zimmermann, N. (2012). Toilets with a biogas/anaerobic digester. Autark Engineering AG, Switzerland.


Document download:

pdf:

Toilets with a biogas/anaerobic digester
[663.3 KB]


« back to previous page